BTZBM - RESINOID BONDED GRINDING WHEELS
- MSDS: BTZBM
- Manufacturer: BATES ABRASIVE INC
- Product Name: RESINOID BONDED GRINDING WHEELS
- National Stock Number: 3460-00N049012
Product Identification
Product ID:RESINOID BONDED GRINDING WHEELS
MSDS Date:10/07/1993
FSC:3460
NIIN:00N049012
MSDS Number: BTZBM
Responsible Party
BURLINGTON, WA 98233
US
Emergency Phone: 800-231-5725
Info Phone: 800-231-5725
Cage: 1V342
Contractor
Telephone: 800-231-5725
Cage: 1V342
Ingredients
GRINDING WHEEL MAY CONTAIN 1 OR MORE OF INGS 2-4
RTECS: 9999999ZZ
OSHA PEL N/K
ACGIH TLV: N/K
ALPHA-ALUMINA (ALUMINUM OXIDE)
CAS: 1344-28-1
RTECS: BD1200000
Fraction By Weight: 87%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
SILICON CARBIDE
CAS: 409-21-2
RTECS: VW0450000
Fraction By Weight: 87%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
ZIRCONIA ALUMINA; (ZIRCONIA ALUMINUM)
Fraction By Weight: 87%
OSHA PEL N/K
ACGIH TLV: N/K
BOND SYSTEM MAY CONSIST OF INGS 6-9
RTECS: 9999999ZZ
OSHA PEL N/K
ACGIH TLV: N/K
FLUORINE; (FLUORIDES AS F)
CAS: 7782-41-4
RTECS: LM6475000
Fraction By Weight: 2%
OSHA PEL 2.5 MG/M3
ACGIH TLV: 2.5 MG/M3
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
CALCIUM OXIDE; (LIME)
CAS: 1305-78-8
RTECS: EW3100000
Fraction By Weight: 2%
OSHA PEL 5 MG/M3
ACGIH TLV: 2 MG/M3
FIBROUS GLASS; (GLASS, FIBROUS OR DUST)
RTECS: LK3651000
Fraction By Weight: 9%
OSHA PEL 15 MG/M3 (DUST)
ACGIH TLV: 10 MG/M3 (DUST)
SILICA, CRYSTALLINE - QUARTZ; (SILICON DIOXIDE)
CAS: 14808-60-7
RTECS: VV7330000
Fraction By Weight: <1%
OSHA PEL N/K
ACGIH TLV: 0.1 MG/M3 RDUST
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: COUGHING, SHORTNESS OF
BRTH. CHRONIC: MAY AFFECT BREATHING CAPACITY. INGEST: NO KNOWN
ADVERSE EFTS, BUT INGESTION NOT RECOMMENDED. SKIN CONT & ABSORP:
SOME MAY EXPERIENCE SKIN IRRIT FROM DUST. EYE: MAY IRRITATE. OTHER
POTNTL HLTH RISKS: GRINDING MAY CREATE ELEVATED SOUND LEVELS WHICH
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-QUARTZ:IARC MONO,
SUPP. VOL 7, PG 341, 1987: GRP 2A. NTP 6TH ANNUAL REPORT ON
CARCINS, 1991:(SUPDAT)
Effects of Overexposure:HLTH HAZ: MAY EFFECT HEARING. TESTS WITH WHEELS
KNOWN TO CONTAIN CRYSTALLINE SILICA DID NOT PRODUCE DETECTABLE
AMOUNT OF RESPIRABLE DUST.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE PREEXISTING
RESPIRATORY CONDITIONS.
First Aid
First Aid:INHAL: REMOVE TO FRESH AIR. ARTF RESP AS NEEDED. OBTAIN MED
ASSISTANCE. INGEST: OBTAIN MEDICAL ASSISTANCE. SKIN: WASH AFFECTED
AREAS WITH SOAP AND WATER. OBTAIN MEDICAL ASSISTANCE. EYE: WASH
WITH LARG E AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. OBTAIN FIRST
AID AND MEDICAL ASSISTANCE, IF NEEDED. OTHER POTNTL HLTH RISKS:
OBTAIN MED ASSIST. THERE IS LIM INFO THAT CRYSTALLINE SILICA IS A
CARCIN.
Fire Fighting
Extinguishing Media:USE WATER.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:NORMAL CLEANUP PROCEDURES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:AS NEEDED. FOR NIOSH/MSHA APPROVED DUST
RESPIRATORS, SEE OSHA 29CFR 1910.134.
Ventilation:LOCAL/MECHANICAL(GEN): RECOMMENDED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:AS NEEDED HEARING PROTECTION. SEE OSHA 29CFR
1910.95 (HEARING PROTECTION).
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP: GREATER THAN GRINDING WHEEL COMPONENTS. COOLANTS MAY
PRODUCE OTHER DECOMPOSITION PRODUCTS. EXPLAN OF CARCIN: ANTIC TO BE
CARCIN.
Chemical Properties
Spec Gravity:2-4
Solubility in Water:SLIGHT
Appearance and Odor:SOLID PRODUCT. MAY GIVE OFF ODOR IN USE
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:IN USE, DUST & DECOMPOSING ODORS ARE
GENERATED. IN MOST CASES, MAT REMOVED FROM WORKPLACE WILL BE
SIGNIFICANTLY (SUPDAT)
Disposal
Waste Disposal Methods:STANDARD LANDFILL METHODS CONSISTENT WITH
APPLICABLE FEDERAL, STATE AND LOCAL LAWS. PRODUCTS WITH LISTED
FLUORIDES MAY HAVE SLIGHTLY SOLUBLE FLOURIDE SWARF.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.